The PC-1100A, PC-2200A, PC-3300A and PC-4420A erasing cabinets are
compact, portable, heavy-duty units designed for high-volume chip erasure!
High UV intensity! Fast erasing times! Large load capacities!
All four models feature high-intensity, short-wave UV (254 nm), ozone-free, low-pressure mercury vapor,
modular quartz grid lamp assemblies mounted on specular aluminum reflectors. The cabinets have large
loading drawers with erasing capacities ranging from 84 to 336 EPROMs. Units also accommodate PC
boards, metric cards and silicon wafers up to 8 inch (203 mm). In addition, the PC-3300A and PC-4420A
cabinets accept open-faced stocking tubes. All of these units provide outstanding UV irradiance uniformity
to ensure quick and complete erasure of programmed memory from every EPROM, chip or wafer. The
PC-1100A, PC-2200A and PC-3300A can each produce erasing times as fast as 5.4 minutes*, while the
PC-4420A can complete an erasing cycle in just 4 minutes!**
 |
PC-1100A
- One low-pressure mercury vapor quartz grid lamp assembly
- Nominal initial short-wave UV intensity of 30,000 μW/cm2
- Load capacity of 84 individual, 24-pin EPROMs
|
 |
PC-2200A
- Two low-pressure mercury vapor quartz grid lamp assemblies
- Nominal initial short-wave UV intensity of 30,000 μW/cm2
- Load capacity of 168 individual, 24-pin EPROMs
|
 |
PC-3300A
- Three low-pressure mercury vapor quartz grid lamp assemblies
- Nominal initial short-wave UV intensity of 30,000 μW/cm2
- Load capacity of 252 individual, 24-pin EPROMs
|
 |
PC-4420A
- Four low-pressure mercury vapor quartz grid lamp assemblies
- Nominal initial short-wave UV intensity of 46,000 μW/cm2
- Load capacity of 336 individual, 24-pin EPROMs
|
*Erasing time based on 6W-sec/cm2 EPROM at nominal initial short-wave UV intensity of 30,000 μW/cm2 at cabinet temperature of 100° F (37.8° C)
**Erasing time based on 6W-sec/cm2 EPROM at nominal initial short-wave UV intensity of 46,000 μW/cm2 at cabinet temperature of 100° F (37.8° C)
Innovative Features:
- Electronic timer — Minimizes operator error and
provides automatic shut-off at the end of the erasing
cycle. Pre-settable up to 60 minutes.
- UV-absorbing light indicators — Alert user when the
corresponding grid lamps are operating
- Safety interlock — Will not allow unit to operate unless
the loading drawer is fully closed. Protects the user
from accidental exposure to hazardous short-wave UV
(254 nm) radiation
- Powerful internal cooling fans — Control cabinet
temperature to ensure optimum UV intensity, maintain
uniform output and provide efficient erasing conditions.
Helps prolong the life of the grid lamps.
- Removable tray insert with built-in conductive foam
pad is provided with the PC-1100A, PC-2200A and
PC-3300A units for quick loading and unloading and
to protect the devices from electrostatic damage. The
tray insert is height adjustable to maintain the optimum
UV exposure distance. A choice of 6 in (152 mm) or 8
in (203 mm) tray inserts is available for the PC-4420A
cabinet.

† UV intensity measured with Spectroline® XR-1000 AccuMAX™ Series
digital radiometer
with XS-254 short-wave UV sensor detector
Replacement Parts & Accessories
EC-0138 ................. Digital timer for PC-4420A (230V/50Hz)
EC-0139 ................. Digital timer for PC-4420A (120V/60Hz)
EC-0172.................. Electronic timer for PC-1100A, PC-2200A and PC-3300A (120V/60Hz)
EC-0173.................. Electronic timer for PC-1100A, PC-2200A and PC-3300A (230V/50Hz)
G750NO2................ Grid lamp assembly for PC-1100A, PC-2200A and PC-3300A
G895NO.................. Grid lamp assembly for PC-4420A
I-1100..................... Tray insert with conductive foam pad for PC-1100A
I-2200..................... Tray insert with conductive foam pad for PC-2200A
I-3300..................... Tray insert with conductive foam pad for PC-3300A
I-4420-6X............... Tray insert for 6 in (152 mm) wafers for PC-4420A
I-4420-8X............... Tray insert for 8 in (203 mm) wafers for PC-4420A |
|